Research and evaluation

Engineering evaluation, published while it is still unflattering.

Clinoria is evaluated with synthetic and adversarial case sets, a frozen development suite and unit tests. There is no clinical trial and no independent validation. What follows is what we test, what we found, and where the evidence stops.

Last updated 6 November 2026 · defect register below is current

Method

What "evaluated" means here.

01 · Development suite

A frozen 12-case ultrasound set

Twelve synthetic ultrasound dictations with known correct findings, used to detect regressions between changes. It is an internal developer evaluation set. It is not a benchmark, not an efficacy study, and not comparable to a published clinical evaluation.

02 · Adversarial cases

Inputs written to break it

Negated red flags, mid-consultation corrections, compound family history, hedged diagnoses, code-switched negation and contradictory answers. These cases exist because each one has caught a real defect.

03 · Unit tests

248 Malayalam-focused tests

The Malayalam suite tests script-based extraction and negation scoping. It does not test transliterated input — which is precisely where the system fails. A passing suite is not a coverage claim.

04 · Defect register

Every reproducible failure, written down

The register below is the primary output of evaluation. A defect that can be named and reproduced is a defect that can be fixed; a defect inside fluent prose is usually never found.

Defect register

Open defects, as of 6 November 2026.

All of the following are reproducible on the current working build. None has been fixed. Publishing them is a condition of asking clinicians to evaluate the system.

Extraction defects 8 open
ID Defect Reproduction Clinical impact Status
R1 Polarity inversion on code-switched negation “Chest pain illa.” Records pain as present when the patient denied it Open
R2 Total recall failure on transliterated Malayalam “Pani undo? Illa, pani illa.” Zero facts; note rendered as empty sections Open
R3 Fabricated laterality, accepted by the validator “chest pain present right now” Invites a wrong-side finding into the record Open
R4 Compound family history loses a relative “My mother has diabetes and my father had a heart attack.” Heritable cardiac risk silently dropped Open
R5 Uncertainty not populated “it might be an early infection…” Hedged impression reads as an assertion Open
R6 Concept conflation in chief complaint “cough and chest pain” Renders “Cough in the chest”, merging two findings Open
R7 Evidence labels inverted on negation “denies chest pain” Denial tagged with a positive-label; traceability misleading Open
R8 Patient's own symptoms default to subject: unknown “I have a cough.” Attribution ambiguous in multi-subject consultations Open

Note on R3 Fabrication survived validation because the validator checks rendered text against the fact graph — and the fact graph itself contained the invented laterality. Self-consistency is not correctness, and this page exists to say so.

One positive result

Fail-closed validation does stop one class of error.

Not every finding is a defect. The validator refused a draft because a rendered severity was not supported by any fact — which is the behaviour the architecture was built for.

Synthetic transcript · hedged impression
Doctor What do you think it is?
Patient It might be an early infection, possibly a mild pneumonia, but he was not sure.

The draft was withheld

The rendered note said “mild pneumonia”. The fact graph contained no severity, because the extractor had not captured it. The validator returned valid: false with the message that severity “mild” was not supported by the graph, and the draft did not reach the review queue.

The underlying uncertainty bug (R5) is still open. But the failure stayed contained instead of being signed.

Verified Fail-closed behaviour, reproducible.

Boundaries of the evidence

What this research is not.

No clinical validation
No independent clinical validation study has been conducted or commissioned. No clinical accuracy figure is published, and no percentage appears anywhere on this site.
No clinical trial
There is no completed multi-centre trial, no regulatory submission and no ethics-approved prospective study.
No external audit
No penetration test, no SOC 2, no ISO 27001, no independent security assessment. See security.
No published benchmark
The 12-case suite is internal. It has not been released, and results on it should not be compared with any external system.
No real patient data
Every example on this site is synthetic. No clinical transcript from a real consultation appears here.
No claim of general Malayalam capability
Malayalam is research. The current build fails on transliterated input, and the defect is listed above as R1 and R2.

Publication policy

How we will report progress.

  1. Defects are listed here while open, not after they are fixed.
  2. When a defect is resolved, it stays on this page with a resolution date and the test that now covers it.
  3. No accuracy percentage will be published until an evaluation with clinician-authored gold documentation supports it.
  4. Negative results are published with the same prominence as positive ones.

The register above is deliberately unflattering. If it ever stops being unflattering, that will be evidence of progress rather than of better presentation.

Evaluate it yourself

A demonstration walks the register with you: each defect is reproduced live on synthetic input so you can judge severity yourself rather than trusting our characterisation of it.

Request a demonstration

Collaboration

The register is the agenda. Help us work through it.

Clinician-authored reference documentation is what turns this list from an engineering backlog into an evaluation.